Issue 6, 2008

Characteristics of dwellings contaminated by moulds

Abstract

Dwellings showing a presence of moulds are considered to be unhealthy both by the inhabitants and by sanitary authorities. Although the thresholds of pathogenicity have not yet been established, the toxic, allergic and infectious risk of indoor moulds is better understood today. A study on indoor fungi contamination for 128 dwellings was done between October and May in France. It concerned 69 dwellings, the occupants of which either complained to the sanitary authorities about problems of moulds and humidity or consulted a doctor who related their symptoms to housing conditions. Fifty-nine other dwellings, the occupants of which were healthy, constituted the control group. We present the statistical analysis of questionnaires, which aimed to clarify characteristics of dwellings associated with high concentrations of airborne moulds. Air samples were taken with an impactor in 500 rooms. On visiting dwellings, investigators obtained answers to 25 questions concerning characteristics of inhabitants and living space, as well as the presence of mould indicators. Indoor and outdoor temperature and indoor relative humidity of air measurements were taken. The total concentration of fungi in the air was significantly higher in ground floor apartments versus those on other floors (p = 0.047), in small and highly occupied dwellings (p = 0.03 and 0.003), in dwellings with electric heating (p = 0.04), without a ventilation system (p = 0.003), with water damage (p = 0.003), and finally, in those where the investigator noted an odour of moisture or visible moulds (p < 0.001). The efficacy of the latter criteria in the evaluation of insalubrity is discussed.

Graphical abstract: Characteristics of dwellings contaminated by moulds

Supplementary files

Article information

Article type
Paper
Submitted
07 Dec 2007
Accepted
02 Apr 2008
First published
29 Apr 2008

J. Environ. Monit., 2008,10, 724-729

Characteristics of dwellings contaminated by moulds

S. Roussel, G. Reboux, A. Bellanger, S. Sornin, F. Grenouillet, J. Dalphin, R. Piarroux and L. Millon, J. Environ. Monit., 2008, 10, 724 DOI: 10.1039/B718909E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements