Exposure assessment by physiologic sampling pump—prediction of minute ventilation using a portable respiratory inductive plethysmograph system

Abstract

A study was conducted to evaluate a portable respiratory inductive plethysmograph (RIP) as a means to estimate minute ventilation ([V with combining dot above]E) for use in controlling the flow rate of a physiologic sampling pump (PSP). Specific aims were to: (1) evaluate the ability of the portable RIP system to measure [V with combining dot above]E using a direct (individual) fixed-volume calibration method (Direct RIP model), (2) develop and evaluate the performance of indirect (group) regression models for [V with combining dot above]E prediction using output data from the portable RIP and subject demographic characteristics (Indirect RIP model), and (3) compare [V with combining dot above]E estimates from indirect and direct portable RIP calibration with indirect estimation models published previously. Nine subjects (19–44 years) were divided into calibration (n = 6) and test (n = 3) datasets and performed step-tests on three different days while wearing the portable RIP and breathing through a pneumotachometer (reference). Minute ventilation and portable RIP output including heart rate, breathing rate, and a motion index were recorded simultaneously during the 80 minute sessions. Calibration data were used to develop a regression model for [V with combining dot above]E prediction that was subsequently applied to the test dataset. Direct calibration of the portable RIP system produced highly variable estimates of [V with combining dot above]E (R2 = 0.62, average % error = 15 ± 50) while Indirect RIP model results were highly correlated with the reference (R2 = 0.80–0.88) and estimates of total volume were within 10% of reference values on average. Although developed from a limited dataset, the Indirect RIP model provided an alternative approach to estimation of [V with combining dot above]E and total volume with accuracy comparable to previously published models.

Graphical abstract: Exposure assessment by physiologic sampling pump—prediction of minute ventilation using a portable respiratory inductive plethysmograph system

Article information

Article type
Paper
Submitted
14 Apr 2008
Accepted
20 Aug 2008
First published
11 Sep 2008

J. Environ. Monit., 2008,10, 1179-1186

Exposure assessment by physiologic sampling pump—prediction of minute ventilation using a portable respiratory inductive plethysmograph system

M. Lin, W. A. Groves, A. Freivalds, E. G. Lee, M. Harper, J. E. Slaven and L. Lee, J. Environ. Monit., 2008, 10, 1179 DOI: 10.1039/B806292G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements