Contents list for Journal of Analytical Atomic Spectrometry, issue 10, 2006
Front cover
J. Anal. At. Spectrom., 2006, 21, 985
DOI: 10.1039/b613189c

Contents
J. Anal. At. Spectrom., 2006, 21, 987
DOI: 10.1039/b613190p
Editorial
Editorial: A new scope for publishing in JAAS
J. Anal. At. Spectrom., 2006, 21, 993
DOI: 10.1039/b611978f
Papers
Multi-elemental speciation analysis of barley genotypes differing in tolerance to cadmium toxicity using SEC-ICP-MS and ESI-TOF-MS
Daniel P. Persson, Thomas H. Hansen, Peter E. Holm, Jan K. Schjoerring, Hans Christian B. Hansen, John Nielsen, Ismail Cakmak and Søren Husted,
J. Anal. At. Spectrom., 2006, 21, 996
DOI: 10.1039/b608701a
Optimisation of a laser ablation cell for detection of hetero-elements in proteins blotted onto membranes by use of inductively coupled plasma mass spectrometry
Ingo Feldmann, Christina U. Koehler, Peter H. Roos and Norbert Jakubowski,
J. Anal. At. Spectrom., 2006, 21, 1006
DOI: 10.1039/b606773e
A model for the generation of small particles in laser ablation ICP-MS
Roland Hergenröder,
J. Anal. At. Spectrom., 2006, 21, 1016
DOI: 10.1039/b604453k
Dual mode sample introduction for multi-element determination by ICP-MS: the optimization and use of a method based on simultaneous introduction of vapor formed by NaBH4 reaction and aerosol from the nebulizer
Alemayehu Asfaw and Grethe Wibetoe,
J. Anal. At. Spectrom., 2006, 21, 1027
DOI: 10.1039/b604116g
Solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry for the direct determination of traces of boron in biological materials using isotope dilution for calibration
M. Resano, M. Aramendía and F. Vanhaecke,
J. Anal. At. Spectrom., 2006, 21, 1036
DOI: 10.1039/b606118d
The application of piecewise direct standardisation with variable selection to the correction of drift in inductively coupled atomic emission spectrometry
Michael L. Griffiths, Daniel Svozil, Paul Worsfold and E. Hywel Evans,
J. Anal. At. Spectrom., 2006, 21, 1045
DOI: 10.1039/b604728a
Isotopic analysis of lead in sub-nanogram quantities by TIMS using a 202Pb–205Pb spike
Y. Amelin and W. J. Davis,
J. Anal. At. Spectrom., 2006, 21, 1053
DOI: 10.1039/b606842a
Correction of matrix effects via scattered radiation in X-ray fluorescence analysis of samples collected on membrane filters
Rafa
Sitko,
J. Anal. At. Spectrom., 2006, 21, 1062
DOI: 10.1039/b604955a
Technical Notes
Determination of iron in plant samples using isotope dilution inductively coupled plasma mass spectrometry with a quadrupole ICP-MS operated in an He/H2 cell mode
Hei-shing Chu, Yiu-chung Yip, Kwok-chu Chan and Wing-cheong Sham,
J. Anal. At. Spectrom., 2006, 21, 1068
DOI: 10.1039/b608022g
Behaviour of a flow focusing pneumatic nebulizer with high total dissolved solids solution on radially- and axially-viewed inductively coupled plasma atomic emission spectrometry
Beatriz Almagro, Alfonso M. Gañán-Calvo, Montserrat Hidalgo and Antonio Canals,
J. Anal. At. Spectrom., 2006, 21, 1072
DOI: 10.1039/b606621f
Atomic Spectrometry Update
Atomic spectrometry update—X-ray fluorescence spectrometry
Philip J. Potts, Andrew T. Ellis, Peter Kregsamer, Christina Streli, Christine Vanhoof, Margaret West and Peter Wobrauschek,
J. Anal. At. Spectrom., 2006, 21, 1076
DOI: 10.1039/b611269m
Back matter
J. Anal. At. Spectrom., 2006, 21, 1108
DOI: 10.1039/b613192c
Back cover
J. Anal. At. Spectrom., 2006, 21, 1111
DOI: 10.1039/b613193j

