Microfluidic sugar paper


Researchers in the US have demonstrated that the speed of fluid in a paper microfluidic device can be controlled by sugar solutions dried onto the paper.

Many chemical tests require washing steps and the addition of reagents in a precisely timed sequence. These steps can be controlled manually, but if they are automated there is less room for human error.

The use of microfluidics to miniaturise assays is now common. However, a simple method for automated sequential reagent addition has yet to be perfected for paper devices. Current methods for creating delays involve redesigning the geometry of the device and the length of incoming channels every time a new test with different fluids is needed. Now, Barry Lutz and colleagues, at the University of Washington, in Seattle, have had the resourceful idea of using sugar to slow down the flow of liquid.

The team created the so-called sugar delays by dissolving sugar at different concentrations and drying it onto paper strips. ‘Sugar delays allow a paper shape to be “programmed” based on the concentration of sugar applied to each leg,’ explains Lutz. The sugar holds back the flow of fluid by anything from a few minutes to an hour. Reagents and buffer salts can be pre-deposited dry and then no further pipetting steps are necessary. Unmeasured amounts of sample and water can be added to the paper and the sugar will make sure that only the right volumes reach the detection zone.

Conceptual illustration (left) and folding card format (right) of paper with dissolvable delays for automated multi-step assay

Microfluidics expert, George Whitesides, from Harvard University, Cambridge, US, likes the elegant idea, being inexpensive and simple as it only involves sugars that are already commonly used as additives to stabilise proteins. ‘As with any new technology, this one will require further development, but the spirit of this work to replace mechanical valves and electrical controllers with autonomous physical processes is exactly correct,’ he says.

This simple automation of multi-step reactions in a paper-based device is a step toward practical and cheap point-of-care immunoassays. The team are now busy creating a whole toolbox of mechanisms along the same lines for flow timing and switching in paper devices. ‘Using paper devices in a point-of-care format could provide earlier diagnosis of diseases such as malaria, dengue fever and HIV, where sensitivity is very important,’ Lutz adds.


Related Content

Faster, cheaper, better

24 September 2014 Premium contentFeature

news image

Microfluidics researchers are aiming to bring new diagnostic devices into mainstream medicine. Mark Peplow reports

Chemistry World podcast - March 2014

4 March 2014 Podcast | Monthly

news image

This month, synthetic DNA bases and chemistry using smartphones

Most Read

Magnetic resonance taken to the limit

21 November 2014 Research

news image

Technique can read the spin of a single nucleus opening up a new way to investigate proteins and complex molecules

Boron and beryllium finally shake hands

24 November 2014 Research

news image

Never-before-seen bond observed between periodic table neighbours

Most Commented

A year of water splitting from one device

21 November 2014 Research

news image

Coating protects electrodes from corrosion to keep photoelectrochemical cell running

Nanostripe controversy in new twist

24 November 2014 Research

news image

Creator of striped nanoparticles insists questions over structures have already been answered and accuses critics of a 'perso...