Issue 3, 2004

Chemical (polycyclic aromatic hydrocarbon and heavy metal) levels in contaminated stormwater and sediments from a motorway dry detention pond drainage system

Abstract

Chemical (polycyclic aromatic hydrocarbon – PAH and heavy metal) levels in stormwater and sediment samples collected from the London Orbital (M25) motorway drainage dry detention pond at Oxted, Surrey, UK were determined. Such chemicals are derived from vehicular combustion products and the wear and tear materials deposited onto the motorway surface. Gas chromatography-mass spectrometry (GC-MS) was used for the qualitative and quantitative determination of 16 USEPA priority PAHs in motorway drainage sediments. The GC-MS method, incorporating a solid phase extraction step, provides detection limits ranging from 0.17 to 0.41 mg kg−1 (dry weight). Almost all of the 16 USEPA listed PAHs were detected. Phenanthrene, fluoranthene, pyrene, benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(a)pyrene and benzo(g,h,i)perylene (PAH numbers 5, 7, 8, 9, 10, 11, 13 and 16) were among the PAHs found at “higher” levels (ranging from 0.3–10.2 mg kg−1, dry weight) in the sediment samples. PAH levels show little change along the motorway drainage silt trap (facility for reducing the levels of suspended particulate matter in the stormwater). PAH concentrations are considerably higher in the dry detention pond outflow interceptor. Statistical analysis showed that significant correlation coefficients (based on a t-test at the 95% confidence interval) were obtained between those PAHs found at high concentrations over all of the sampling sites. Several PAHs were dispersed beyond the treatment facility and accumulation in the sediment of the deer park resulted in levels ranging from 0.3–1.6 mg kg−1, dry weight. These PAHs found beyond the treatment facility (in the local farm deer park) may contribute a serious health threat to farm animals or even fish in the aquatic environment. Heavy metal levels (V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo, Cd, Sb and Pb) of the drainage stormwater and sediments were determined by inductively coupled plasma mass spectrometry (ICP-MS), with quality control evaluation using two certified reference materials. Typical detection limits were found to be below 0.1 µg l−1 for stormwater and 0.005 mg kg−1 for acid digested sediments. Raised heavy metal levels were found throughout the dry detention pond facility and only decrease when the stormwater is diluted following discharge into the river Eden. Statistical analysis also confirms that some significant correlations exist between various heavy metals and PAHs. However, no overall conclusive trend is found indicating that a particular PAH is deposited in sediment relative to a specific heavy metal/s. These results raise some serious concerns about the dispersion and accumulation of chemicals in the sediments of motorway stormwater drainage systems and the need for maintenance and clean-up of contaminated material from such systems.

Article information

Article type
Paper
Submitted
05 Aug 2003
Accepted
15 Jan 2004
First published
13 Feb 2004

J. Environ. Monit., 2004,6, 175-181

Chemical (polycyclic aromatic hydrocarbon and heavy metal) levels in contaminated stormwater and sediments from a motorway dry detention pond drainage system

R. Kamalakkannan, V. Zettel, A. Goubatchev, K. Stead-Dexter and N. I. Ward, J. Environ. Monit., 2004, 6, 175 DOI: 10.1039/B309384K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements