Evaluation of infrared femtosecond laser ablation for the analysis of geomaterials by ICP-MS

Abstract

The capabilities of an infrared (IR) Ti:sapphire femtosecond laser (≈800 nm) to ablate and analyze geomaterials such as monazite, zircon and synthetic glass reference materials is evaluated, with emphasis on U/Pb ratio determinations useful for dating accessory minerals in rocks. We particularly discuss the influence of pulse duration (respectively 60, 200, 350, 500, 670, 830, 2000 and 3000 fs) on the internal precision (2 min ablation), reproducibility over two weeks and accuracy of quadrupole ICP-MS measurements. The best results for all these criteria are obtained when using the shortest pulse duration (60 fs). It was found that internal precision and reproducibility were improved by a factor of 3 and 4, respectively, from picosecond to 60 fs pulsewidths. Reproducibility at this pulse duration for U/Pb ratio determinations is of 2% RSD or better, depending on the material analyzed, and this ratio is accurate within this uncertainty. Lead isotopic ratios also benefit from the shortest pulsewidth. They are measured at 60 fs with a precision (<0.5% RSD) approaching the limitations of quadrupole ICP-MS. Preliminary data were also obtained using the 3rd harmonic (≈266 nm) of the Ti:sapphire fundamental wavelength and they are compared with the infrared mode. There seems to be no obvious analytical benefit to switch from IR to UV in the femtosecond laser ablation regime. Analyses of zircon 91500 with IR pulses led to better repeatability, around 0.9% (10 values, 1σ), compared to 3% for the UV pulses. The accuracy appears to be comparable for the two wavelengths.

Graphical abstract: Evaluation of infrared femtosecond laser ablation for the analysis of geomaterials by ICP-MS

Article information

Article type
Paper
Submitted
20 Jun 2007
Accepted
24 Jan 2008
First published
25 Feb 2008

J. Anal. At. Spectrom., 2008,23, 702-710

Evaluation of infrared femtosecond laser ablation for the analysis of geomaterials by ICP-MS

R. Freydier, F. Candaudap, F. Poitrasson, A. Arbouet, B. Chatel and B. Dupré, J. Anal. At. Spectrom., 2008, 23, 702 DOI: 10.1039/B709415A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements