Phishing warning 01-May-2024
We are aware of phishing emails targeting speakers of events whose names appear on our events pages. If you are unsure if an email regarding event registration or accommodation has come from us please contact us and do not provide any credit card details or personal information

4-day Comprehensive GC-MS Training (Varian Ion Trap with MSWorkstation),

28 February 2017 09:00 - 3 March 2017 17:00, Milton Keynes, United Kingdom


Introduction

The four-day Comprehensive GC-MS Training course introduces the fundamental theory of ion trap GC-MS along with the operation, maintenance and troubleshooting of the Varian Saturn 2200 ion trap using MSWorkstation software.

This course includes an introduction to ion trap mass spectrometry; hardware configuration; MS tuning; data acquisition in scan and MS/MS modes; qualitative & quantitative data analysis; reports; and sequencing.

The course will train the operator to perform the maintenance required to ensure the smooth running of the instrument. The course also discusses the principles of troubleshooting by examining the effects of faults in the system on the chromatographic output. This course includes an introduction to troubleshooting and maintenance focusing on tunes & diagnostics, GC considerations, vacuum system, ion source, ion trap mass filter and MS detector.

It combines a mixture of classroom based presentations with hands-on software and hardware lab exercises, to give you comprehensive training.

You can attend all 4 days of the course for a complete training solution. Alternatively you can attend the 2-day Comprehensive GC-MS Hardware (Varian Ion Trap) course or 2-day Comprehensive GC-MS Software Training (Varian MSWorkstation) course for specific training on hardware or software.

For training on the GC hardware please see the 2-day Comprehensive GC Hardware Training (Varian GC) course.

Learning Outcomes

  • You will learn the theory & principles of mass spectrometry focusing on the ion trap GC-MS
  • You will become familiar with the Varian Saturn 2200 Ion Trap Mass Spectrometer instrumentation learning about the function & operation of individual components
  • You will gain experience of adjusting the important MS parameters
  • You will gain practical experience of performing maintenance of each MS component including vacuum system, ion source, ion trap mass filter & detector
  • You will learn the strategies and gain practical experience of instrument troubleshooting
  • You will learn the operation of the MSWorkstation software
  • You will learn installation, set-up and have an overview of the software
  • You will learn about the different tuning methods, undertake air/water checks & an autotune then interpret the results
  • You will learn how to create a full scan and an MS/MS method to gain an understanding of each method type
  • You will analyse individual samples and create sequences for analysing multiple samples
  • You will undertake qualitative data analysis 
  • You will undertake quantitative data analysis creating calibration curves and producing appropriate sample reports​
Venue
The Open University

The Open University, Walton Hall, Milton Keynes, MK7 6AA, United Kingdom