Inductively coupled plasma mass spectrometry, coincidence laser spectroscopy (ICP-MS-CLS), simulation of the transmission efficiency of a 3D quadrupole ion trap for cooling energetic ions from the ICP prior to optical detection

Abstract

A fundamental requirement of ICP-MS-CLS is a post mass separation ion beam with an energy spread of less than ∼0.2 eV to enable efficient pumping of fluorescent lines with a narrow band (Δν ∼ 100 kHz) laser for the optical detection step. The role of a 3D quadrupole ion trap for ion beam cooling, as an accessory for a new generation of ICP-MS-CLS (inductively coupled plasma mass spectrometry, coincidence laser spectroscopy) (B. L. Sharp, P. S. Goodall, L. M. Ignjatović and H. Teng, J. Anal. At. Spectrom., 2007, 22, 1447) instrument, was investigated by means of numerical simulation. Whereas in-trap ion cooling is well established, it was found that extraction of cooled ions from the trap introduced additional broadening and a loss of transmission efficiency. Modelling was based on a beam of 20 eV mean energy with a spread of 3 eV which represents a worst case scenario for the ions derived from an ICP source. The efficiency of the cooling process (trapping + extraction), as well as the energy distributions of ions exiting the trap, were calculated and compared for several methods of extraction. Trapping efficiencies of ∼25% were obtained at buffer gas pressures up to 10 mTorr. The addition of virtual reflectrons to the trap resulted in an improvement in the energy distribution of the trapped ions by lowering the wings of the distribution, but did not significantly improve the efficiency. Zero field, rf field only, quadrupolar field and homogeneous field ion extraction were investigated to recover ions from the trap, and of these quadrupolar extraction was best. However, extraction efficiency and ion energy distribution were inversely related so that quadrupolar extraction at Uq = 10 V yielded an exit ion energy distribution of 0.5 eV half width, compared with a trapped width of 0.03 eV, but with only 10% transmission efficiency. Thus, it was demonstrated that a 3D trap can be used to cool energetic ions for post-trap mass or spectroscopic examination, but the low efficiency makes it unsuitable for use with ICP-MS-CLS.

Graphical abstract: Inductively coupled plasma mass spectrometry, coincidence laser spectroscopy (ICP-MS-CLS), simulation of the transmission efficiency of a 3D quadrupole ion trap for cooling energetic ions from the ICP prior to optical detection

Article information

Article type
Paper
Submitted
03 Jan 2008
Accepted
13 Mar 2008
First published
11 Apr 2008

J. Anal. At. Spectrom., 2008,23, 985-991

Inductively coupled plasma mass spectrometry, coincidence laser spectroscopy (ICP-MS-CLS), simulation of the transmission efficiency of a 3D quadrupole ion trap for cooling energetic ions from the ICP prior to optical detection

B. L. Sharp, L. M. Ignjatovic and P. S. Goodall, J. Anal. At. Spectrom., 2008, 23, 985 DOI: 10.1039/B800035B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements